Download Inhoudsopgave Inhoud Print deze pagina

Washing And Sanitizing The Components; Reassembling The Washed Components - CombiSteel 7537.0005 Gebruikershandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

7.4 Washing and sanitizing the components

All of the previously disassembled and removed
components must be thoroughly washed and sanitized.
lmportant: the sanitizing solution must
comply with the regulations in force at the
time the machine is used.
To carry out the procedure correctly, please use the
following instructions:
1. Fill a container with a sanitizer solution mixed in water
(2% of sodium hypochlorite mixed in water).
2. Thoroughly wash the tank, lid and evaporator with a
sponge soaked in the sanitizer solution.
3. Thoroughly wash again with clean water.
4. Fill another container with a sanitizer solution.
5. Dip the dismantled components into the sanitizer
solution.
6. Leave the dismantled components to soak in the
solution for 30 minutes.
7. Thoroughly wash again with clean water.
8. Place the components on a clean surface and dry them.
9. Assemble the machine as described in part 7.510.
before using the machine again carry out the rinsing cycle
with clean water (part 7.6).
Warning: do not submerge lids equipped
with lighting in any type of liquid. Before
starting
the
operations of the lid, remove it from the machine as
described in the previous chapter.
To clean the lighted lid correctly, proceed as follows:
1. Using a clean, damp cloth, first wipe clean the bottom
part of the lid (in contact with the product).
2. Using a clean, damp cloth, wipe clean the whole outer
part.
3. Using a sponge dipped in sanitizing solution, sanitized
the bottom part of the lid, taking care not to wet the
contacts (X).
4. Allow to act for 30 minutes.
5. Rinse twice or more, only the bottom part, with a clean
sponge soaked in fresh water.
6. Place the lid on a clean surface and dry it; first dry the
bottom and then the outer part by means of a clean cloth.
cleaning
and
sanitizing
www.combisteel.com
7. Set the lid back in place only after having cleaned and
sanitized the bow.
lt is forbidden to wash and/or sanitized the
lid while it is installed in the machine.

7.5 Reassembling the washed components

All of the washed and sanitized components must be
carefully reassembled. Some components must be
adequately lubricated in order to ensure that they work
efficiently.
Apply the seal (A) on the auger as shown in the figure
below.
Always check the seal integrity; should it be
worn, replace it with a new one.
Replace the seal (A) once a year at least.
Using the Vaseline provided, lubricate the seal (A) in the
areas shown in the figure below.
16

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

7537.00107537.0015

Inhoudsopgave