Before effecting any intervention on the electrical parts of the appliance,
the connection to the network must be interrupted.
The connection of the appliance to earth is mandatory.
The manufacturer declines all responsability for any inconvenience
resulting from the none observance of this condition.
Connection of the power supply cable
Warning:
If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
* Unhook the terminal board cover by inserting a screwdriver into the two hooks
"A" (fig. 9.1).
* Open the cable gland by unscrewing screw "F" (fig. 9.2), unscrew the terminal
screws.
* Insert the feeder cable of the suitable section (as described in the next
chapter) into the cable gland.
* Connect the phase and earth cables to the terminal block according to the
diagram in figure 9.3.
* Pull the feeder cable and block it with cable gland.
* Close the terminal block cover (check the two hooks "A" are correctly hooked).
Important
To connect the power supply cable DO NOT unscrew the screws fixing the
cover plate behind the terminal block.
N.B.
The earth conductor must be left about 3 cm longer than the others.
253