Foutmelding
Service 33.2
Gas burner failed close gas
supply
Service 33.3
Gas burner failed close gas
supply
Service 34.32
Data communication failed
Service 60
Gas system failed
13.3.3
Foutmeldingen verwarming hete lucht
Foutmelding
Service 20.1
Cabinet sensor failed
Service 28.1
Steam generator too hot
Service 28.2
Cooking cabinet too hot
Service 34.1
Data communication failed
Service 34.2
Data communication failed
Service 34.4
Data communication failed
Service 42.3
Solenoid valve failed
Service 42.6
Solenoid valve failed
Service 43.3
Solenoid valve failed
13.3.4
Foutmeldingen vocht
Foutmelding
Service 20.2
Control sensor failed
Service 20.4
Humidity sensor failed
Service 30
Humidity control failed
Service 36
Originele handleiding
Oorzaak
De gasbrander is defect.
Draai de hoofdkraan van de gasleiding
dicht.
De gasbrander is defect.
Draai de hoofdkraan van de gasleiding
dicht.
De interne datacommunicatie verloopt
gebrekkig.
De initialisering van de ontsteking is
defect.
Schakel het apparaat uit en opnieuw aan.
Wanneer de foutmelding blijft bestaan,
moet u contact opnemen met uw
servicepartner.
Oorzaak
De thermometer is defect.
De temperatuurlimiet van de
stoomgenerator is overschreden.
De temperatuurlimiet van de ovenruimte
is overschreden.
De interne datacommunicatie verloopt
gebrekkig.
De interne datacommunicatie verloopt
gebrekkig.
De interne datacommunicatie verloopt
gebrekkig.
De watertoevoer is defect.
De watertoevoer is defect.
De interne watertoevoer gaat niet meer
dicht.
Oorzaak
De thermometer is defect.
De thermometer is defect.
De vochtigheidsmeting is defect.
De drukverschilsensor is defect.
13 | Inspiratie en ondersteuning
Bereiding mogelijk
Nee
Nee
Ja
–
Bereiding mogelijk
Nee
Nee
Nee
Nee
Nee
Nee
U kunt niet meer beschikken
over de functie Stoomstoot.
Ja
U kunt alleen nog beschikken
over de bedrijfsmodus
Hetelucht.
Bereiding mogelijk
Ja
Ja
Ja
Ja
59 / 72