2. Layout and items supplied

2.1 Layout (Fig. 1)
1. Laser outlet
2. Sensor
3. On/Measure switch
4. Battery compartment cover
5. Display
6. SET button
7. LASER button
8. Up arrow button
9. Down arrow button
10. °C/°F button
11. Info LED

2.2 Display in measuring mode (Fig. 2)

a. Above/below threshold value
b. Emissivity
c. Ambient temperature
d. Surface temperature
e. Temperature unit of measurement
f.
Battery capacity
g. Measurement
h. Laser active/inactive
2.3 Items supplied
Please check that the article is complete as
specifi ed in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
instructions.
Open the packaging and take out the equip-
ment with care.
Remove the packaging material and any
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage.
If possible, please keep the packaging until
the end of the guarantee period.
Anl_TC_IT_550_SPK13.indb 12
Anl_TC_IT_550_SPK13.indb 12
GB
Danger!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suff ocating!
Original operating instructions
Infrared Thermometer

3. Intended use

The infrared thermometer is suitable for measu-
ring the ambient temperature or surface tempera-
ture of solid substances.
The infrared thermometer is not suitable for
measuring the temperature of people or animals
or for measuring the surface temperature of food,
liquids or gases.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

Power supply: ................ 2 x 1.5V; Type AA (LR6)
Measuring range: ..................... - 50 ° to + 550 °C
Ideal operating temperature: ............. 0 ° to 50 °C
Accuracy at 0 ° to 500 °C: ...................... +/- 2 °C
Accuracy at - 50 ° to 0 °C: ...................... +/- 3 °C
range: .................................................. 0.3-1.2 m
Measuring time: ...........................................0.5 s
Laser class: ...................................................... 2
Laser wavelength: .......................... 630 - 670 nm
Weight: .......................................................0.2 kg
- 12 -