INSTALLATION
SAfETY
INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1
General safety instructions
We can only guarantee trouble-free function and operational reli-
ability if original spare parts intended for the appliance are used.
6.2
Regulations, standards and instructions
Note
Observe all applicable national and regional regulations
and instructions.
7.
Appliance description
7.1
Standard delivery
Delivered with the appliance:
- Signal anode
- Temperature sensors
- Heat conducting paste
- Thermometer
- additional type plate
- Label "Signal anode information"
7.2
Accessories
7.2.1 SVGW-approved accessories
Charging station
Heat transfer stations absorb heating circuit energy by means
of a plate heat exchanger. Heating energy for DHW heating is
transferred into the cylinder primary circuit. The heat transfer
stations are equipped with one circulation pump for each of these
circumstances.
7.2.2 Further accessories
Safety assemblies and pressure reducing valves
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
Flanged immersion heaters and thermal insulation
In addition, flanged immersion heaters and thermal insulation are
available as accessories.
WWW.STIEBEL-ELTRON.COM
8.
Preparations
8.1
Installation site
f Always install the appliance in a room free from the risk of
f
frost and near the draw-off point.
f Ensure that the floor is even and has sufficient load bear-
f
ing capacity and check the height of the room (see chapter
"Specification / Data table").
Minimum clearances
≥200
The minimum side clearances can be swapped to left or right.
f Observe minimum distances.
f
8.2
Transport
Use the lifting eyes at the top of the appliance to assist handling.
SBB 751-1001 | SBB 751-1001 SOL |
≥600
19