Operation
Starting up
EN
6
To start up the machine carry out the following
steps:
Make sure that the main switch (6) is set to off;
Take off the bowl lid (1)
Fill the boiler tank (12) with water using the boiler
tank level indicator tray, until it reaches the max-
imum value indicated on the tray itself, which is
marked –MAX-.
Warning: fill the boiler tank by pouring in water
slowly and check for a few seconds to make sure
that the water level has reached the –MAX-level
and that it is stable.
When filling an empty boiler tank for the first
time, the amount of water needed to completely
fill the tank is approximately 3.5 litres.
Open the bowl lid (1) and pour the chocolate into the
bowl (2).
• Never exceed the maximum level, which is
marked –MAX LEVEL - on the bowl (2) on the tray
itself.
• After pouring the chocolate into the bowl, fit the
lid back in place.
• Then, connect the power plug to a suitable elec-
trical power supply.
• Press the main switch (6) to start the machine;
the product inside the bowl will start to be mixed:
Green indicator light up: Machine switch ON
Green indicator off: Machine switch OFF
• Set the temperature regulator (7) to the desired
temperature in order to heat the chocolate inside
the bowl (2).
Note: There is a RESET button for the temperature
sensor inside. The temperature sensor will shut
down the machine. Then you need to press the re-
set button to restart the machine (See para. 1.14).