Troubleshooting
Problem
Cause
Does not heat
No power
Main switch (6) set to OFF
Temperature sensor activated
Temperature regulator (7) set to
0°C
Mixing paddle
No power
does not turn
The driving shaft is not properly in
place
Motor fault
Main switch (6) set to OFF
Tap leaks
It has not been fit correctly
The outlet and rubber are dirty
The sealing gasket needs
replacing
Water is
Temperature too high
escaping from
The sealing gasket of the level
the level tank
tube needs replacing
The water level is above the MAX
indication when the machine is at
room temperature
Product leaks
The bowl has not been fit correctly
from the
in place
bottom of the
The seal needs replacing
transparent
bowl
Machine
The temperature sensor activated
shutdown
If the machine malfunctions due to causes other than those listed in this table or the proposed remedies do
not solve the problem, contact a specialized technician.
Remedy
Make sure that the machine is plugged in properly
Set the switch to -ON-
Reset the temperature sensor as directed in section
6.1.
Adjust the temperature regulator (7)
Make sure that the machine is plugged in properly
Remove the shaft and then insert it correctly as
directed in section 1.8.
Contact service personnel
Press the switch on
Empty the machine and fit the tap as directed in
section 1,4.
Empty the machine and clean the entire tap throughly;
fit it back on the machine as directed in section 1.4.
Contact service personnel
Lower the temperature
Contact service personnel
Allow the machine to cool down and empty the boiler
until reaching the level indicated
Empty the machine, remove the bowl and fit in place
according to the instructions provided in section 1.3.
Contact service personnel
Unplug & let cool down the machine completely. Then,
RESET the temperature sensor according to the
section 1.14.
EN