On some hob burners, the injector
is covered with a metal piece. This
metal cover must be removed for
injector replacement.
6. Install the new gas injectors. (Tighten-
ing torque 4 Nm)
7. Check all connections in order to make
sure that they are installed safely and
securely.
New injectors have their position
marked on their packing or injector
table on can be referred to.
8. You must check for leakage injectors
after connection.
Unless there is an abnormal condi-
tion, do not attempt to remove the
gas burner taps. You must call an
Authorised service agent or techni-
cian with licence if it is necessary
to change the taps.
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjusted
and turn the knob to the reduced posi-
tion.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver
to adjust the flow rate adjustment
screw.
4. For LPG (Butane - Propane) turn the
screw clockwise. For the natural gas,
you should turn the screw counter-
clockwise once.
ð The normal length of a straight
flame in the reduced position
should be 6-7 mm.
5. If the flame is higher than the desired
position, turn the screw clockwise. If it
is smaller turn anticlockwise.
6. For the last control, bring the burner
both to high-flame and reduced posi-
tions and check whether the flame is on
or off.
7. Depending on the type of gas tap used
in your appliance the adjustment screw
position may vary.
1
Flow rate adjustment screw
Flow rate adjustment screw
1
Leakage check at the injectors
Before carrying out the conversion on the
product, ensure all control knobs are
turned to off position. After the correct
conversion of injectors, for each injectors
should be gas leak checked.
1.
Make sure that the gas supply to the
product is on, still maintaining all con-
trol knobs turned to off position.
2.
Each injector hole is blocked with a
finger applying reasonable force to
stop the gas leakage when corres-
EN / 30