connections parts to be used may vary ac-
cording to the gas type and country regu-
lations.
Leakage Seal :
Connection piece EN 10226 R1/2" :
Connection piece for liquid gas (G30,G31) :
Gas outlet connection piece :
Blind plug :
Making the gas connection - NG
• Natural gas installation must be pre-
pared suitably for the assembly before
installing the product. There must be a
natural gas valve at the outlet of gas
system to be connected to the product.
• Make sure that the natural gas valve is
readily accessible.
• Connect your product to the natural gas
system in your home with a flexible gas
hose that complies with local standards.
• A new sealing gasket must be used while
making the gas connection.
• The gas supply must be connected via a
gas pipe or a safety gas hose with
threaded fittings at both ends.
EN ISO 228 G1/2" type connection
1. Insert the new sealing gasket into the
safety gas hose/pipe. Make sure the
gasket is seated correctly.
2. Secure the gas connection piece to the
appliance with using a 22 mm spanner
and place the connection piece into the
connection piece using a 24 mm span-
ner.
3. You must check for leakage of the con-
nection part after connection.
EN 10226 R1/2" type connection
1. Place the new seal in the connection
piece and make sure the seal is seated
correctly.
2. While holding the gas connection outlet
of the product fixed with a 22 spanner,
connect the interconnection piece to
the product gas outlet with a 24 span-
ner and tighten securely.
3. Insert the new sealing gasket into the
safety gas hose/pipe. Make sure the
gasket is seated correctly.
4. Connect the threaded part of the safety
gas hose/pipe to the interconnector
with the 24 mm spanner and tighten se-
curely, holding the interconnector in
place with the 24 mm spanner.
EN / 27
EN
NL