Download Inhoudsopgave Inhoud Print deze pagina

Product Information; Type Key; Rated Power P2 In Kw; Technical Data - Wilo VeroLine-IPL-Z Inbouw- En Bedieningsvoorschriften

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

en
5

Product information

5.1

Type key

5.2

Technical data

46
Non-permitted substances in the fluid can destroy the pump. Abrasive solids (e.g. sand)
increase pump wear.
Pumps without an Ex rating are not suitable for use in potentially explosive atmo-
spheres.
Highly flammable materials/fluids should always be kept at a safe distance from the
device.
Never allow unauthorised persons to carry out work.
Never operate the pump beyond the specified limits of use.
Never carry out unauthorised conversions.
Use authorised accessories and genuine spare parts only.
Typical installation locations are technical rooms within the building with other domestic
installations. No provision has been made for direct installation of the pump in rooms used
for other purposes (residential and work rooms).
Outdoor installation requires a corresponding, special version (motor with anti-condensa-
tion heater). See chapter "Anti-condensation heater connection".
The operator must use the pump in accordance with national requirements for drinking wa-
ter hygiene and the risk of corrosion. This also includes making sure that stagnation does
not occur and that specific flow velocities are maintained.
Example:
IPL-Z 32/125-1,1/2-K1
IPL-Z
Flange-end pump as inline single pump
DPL-Z
Flange-end pump as inline twin-head pump
-Z
Circulator for domestic hot water
32
Nominal diameter DN of the flange connection in mm
125
Nominal impeller diameter in mm
1.1

Rated power P2 in kW

2
Number of poles, motor
-xx
Variant, e.g. K1
1)
Does not correspond to the actual impeller diameter. Use the spare parts catalogue for
spare parts.
Table 1: Type key
Property
Rated speed
Nominal diameters DN
Pipe and pressure measure-
ment connections
Installation and operating instructions • Wilo-VeroLine-IPL-Z, Wilo-VeroTwin-DPL-Z • Ed.01/2024-07
1)
Value
(2-/4-pole):
2900 rpm or
1450 rpm
IPL-Z: 32 mm
DPL-Z: 32 – 40 mm
Flanges PN 10/16 in accord-
ance with DIN EN 1092-2
with pressure measurement
connections Rp ⅛ in accord-
ance with DIN 3858.
Note
Depending on pump type
Depending on pump type
Standard version

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Verotwin-dpl-z

Inhoudsopgave