Download Print deze pagina

TEUPEN LEO 21 GT Vertaling Van De Originele Handleiding pagina 360

Advertenties

English
Input and output cables
INPUT: multiwires cable 3x2.5mm².
OUTPUT (currents up to 25A): Flex cable 6mm² (red wire for the positive pole, black wire for the negative).
OUTPUT (currents up to 50A): Flex cable 10mm² (red wire for the positive pole, black wire for the negative).
OUTPUT (currents up to 80A): Flex cable 16mm² (red wire for the positive pole, black wire for the negative).
OUTPUT (currents up to 100A): Flex cable 25mm² (red wire for the positive pole, black wire for the negative).
Auxiliary inputs and outputs cable
Connettore super seal 6 vie FE
PIN
Colore filo
1
White
2
Brown
3
Violet
4
Grey
5
Pink
6
Red/Blue
Connettore super seal 5 vie MA
PIN
Colore filo
1
Grey/Pink
2
White/Yellow
3
Yellow/Brown
4
White/Grey
5
Grey/Brown
Alarms
(display version)
When an alarm situation stopping the charge occurs, the display shows one of the information below according failure detected:
Alarm table list here following:
CODE
A01
A02
A03
A05
HIGH BATTERY TEMPERATURE
A07
A08
A09
A10
A11
NO MAINS PRESENCE
A13
BATTERY DISCONNECTED
A14
A15
THERMAL SENSOR FAILURE
A16
A17
A18
A20
A21
A22
A23
A24
WRONG INPUT MAINS
Notes:
A05:
The charge restarts once the battery temperature reaches a value lower than 45°C.
D01911-01
SG3 CAN Bus Interface
Descrizione
AUX1 COM
AUX1 NO
AUX1 NC
AUX2 COM
AUX2 NO
AUX2 NC
Descrizione
Thermal sensor PT100
Thermal Sensor NPT100
Remote Led COM
Remote Led Verde
Remote Led Rosso
<A> <alarm code identified with a 2 digits code>
ALARM TYPE
LOGIC FAILURE #1
CAN BUS KO
WATCHDOG
OVERCURRENT
HIGH TEMPERATURE
MISMATCH VOLTAGE
TIMEOUT
SHORT OUTPUT
LOGIC FAILURE #2
LOW MAINS LEVEL
EEPROM CHECKSUM
RTC/EEPROM KO
FLASH CHECKSUM
HIGH MAIN LEVEL
POWER FAILURE #1
Connettore supe-seal 5 vie FE
PIN
Colore filo
1
Blue
2
Yellow
3
Green
4
Brown / Green
5
White/ Green
DESCRIPTION
Trouble on current detection
Trouble on CAN communication
Logic board mis-working
Battery temperature higher than 55°C
Over current
Battery charter high temperature
Battery voltage sensing error
Phase 1 finished for timeout
Input grid failure
Battery disconnected
Short circuit at the output stage
Thermal sensor not connected o failed
Logic supply failure
Mains level too low
EEPROM memory corrupted
RTC/EEPROM handling error
Microcontroller flash corrupted
Mains level too high
Output current sensing circuit damaged
Input mains level out of the operating range
Descrizione
CAN NEG
CAN H
CAN L
CAN L
CAN HT: 120Ω termination resistor
internally connected to CAN H
STOP
YES
NO
YES
Temporary
Temporary
Temporary
Temporary
YES
YES
Temporary
YES
No
Temporary
Temporary
YES
YES
YES
Temporary
YES
YES
11