Charging curve selection (display version)
You can press the MODE button according two modalities:
1.
Long pressure (at least 1 second): along the battery charger setting it means ENTER
2.
Short pressure (less than 1 second): along the battery charger setting it means ROLL.
Setting:
1.
While pressing the MODE button light on the equipment.
2.
ROLL: select the branch type:
from 1 to 19 identifies a STAND-ALONE charger.
3.
ENTER: branch type confirmation. Next selection is choose the Battery type (Lead acid type corresponds to BA1, Gel corresponds
to BA2 otherwise Ion-Li corresponds to BA3).
4.
ENTER: Battery type confirmation: next level is to select the Charging curve (only for BA1 and BA2).
5.
ROLL: select the desired Charging curve.
Availability is on 4 charging curves:
a.
CU1: IUIa curve plus equalization and maintenance;
b.
CU2: IU1U2ob curve;
c.
CU3: power supply;
6.
ENTER: Charging curve confirmation: now select the Capacity (only for CU1 and CU2).
7.
ROLL: Capacity selection.
Starting point is a nominal value and by the ROLL you can select a value included between 50% and 140% of the nominal in steps of
10%. On the display it is shown the last capacity selected.
8.
ENTER: Capacity confirmation: then you can select the Recharging time (in hours).
9.
ROLL: Recharging time confirmed .
Starting from a suggested Recharging time (according to the capacity chosen at the previous step ) this time can only be increased
up to 20 hours max.
10.
ENTER: Recharging time confirmation: the battery charger goes to a stand-by modality waiting that the output cables being
connected to the battery binding-clamps (if connections have been done already before starting the setting, once arrived at point 10
the charger immediately starts).
Warning: if some trouble or mistake may occur along setting procedure, switch off the battery charger, then switch it on again by keeping
pressed the MODE button and restart setting operation from the beginning.
Compensation setting of the voltage drop on output cables (display version)
While charging, with a long pressure of Mode Button, you can program the voltage cables drop. Execute the following operations while
charger is at maximum current.
1.
Knowing the size and length (positive plus negative lengths) of the output cables, compute the voltage drop at the maximum output
current.
2.
Press shortly the MODE button (ROLL) until reaching the nearest voltage value to the desired one: it is possible to ROLL parameters
between 0,0V e 1,5V with steps of 0,1V.
3.
Press long the MODE button (ENTER) to confirm.
Charging curve (version without display)
The charger is provided of only one charging curve, which is IUIa type and includes equalization and maintenance (unless differently
specified in the enclosed additional document, please read it to verify parameters.). The curve can be regulated through CANBUS protocol.
Connections
OUT
AUX
10
SG3 CAN Bus Interface
English
IN
D01911-01