North American Certifications
Factory Mutual (FM)
8732EM Transmitter
Note:
For Intrinsically Safe (IS) 4-20mA and Pulse Outputs on the 8732EM,
output code "B" must be selected.
N5 Non-Incendive for Class I, Division 2, Groups ABCD: T4
Dust-Ignition Proof for Class II/III, Division 1, Groups EFG: T5
-50°C
Ta
60°C
Enclosure Type 4X, IP66
Install per drawing 08732-2062
Special Conditions for Safe Use (X):
1.
Units marked with "Warning: Electrostatic Charging Hazard"
may either use non-conductive paint thicker than 0.2 mm or
non-metallic labeling. Precautions shall be taken to avoid
ignition due to electrostatic charge on the enclosure.
2.
The intrinsically safe 4-20mA and pulse output cannot
withstand the 500V isolation test due to integral transient
protection. This must be taken into consideration upon
installation.
3.
Conduit entries must be installed to maintain the enclosure
ingress rating of IP66.
4.
Unused conduit entries must use either used the Rosemount-
supplied blanking plugs, or blanking plugs certified in
accordance with the protection type.
K5 Explosion-Proof for Class I Division 1, Groups CD: T6
Non-Incendive for Class I, Division 2, Groups ABCD: T4
Dust-Ignition Proof for Class II/III, Division 1, Groups EFG: T5
-40°C
Ta
60°C
Enclosure Type 4X, IP66
Install per drawing 08732-2062
Special Conditions for Safe Use (X):
1.
Units marked with "Warning: Electrostatic Charging Hazard"
may either use non-conductive paint thicker than 0.2 mm or
non-metallic labeling. Precautions shall be taken to avoid
ignition due to electrostatic charge on the enclosure.
2.
The intrinsically safe 4-20mA and pulse output cannot
withstand the 500V isolation test due to integral transient
protection. This must be taken into consideration upon
installation.
3.
Conduit entries must be installed to maintain the enclosure
ingress rating of IP66.
4.
Unused conduit entries must use either used the Rosemount-
supplied blanking plugs, or blanking plugs certified in
accordance with the protection type.
34
8705-M and 8711-M/L Flowtube
Note:
When used in hazardous (classified) locations, the 8705-M and
8711-M/L may only be used with a certified 8732EM transmitter.
N5 Non-Incendive with Intrinsically Safe Electrodes
for Class I, Division 2, Groups ABCD: T3...T5
Dust-Ignition Proof for Class II/III, Division 1, Groups EFG: T2...T5
-29°C
Ta
60°C
Enclosure Type 4X, IP66/68 (IP68 remote mount only)
Install per drawing 08732-2062
Special Conditions for Safe Use (X):
1.
Units marked with "Warning: Electrostatic Charging Hazard"
may either use non-conductive paint thicker than 0.2 mm or
non-metallic labeling. Precautions shall be taken to avoid
ignition due to electrostatic charge on the enclosure.
2.
If used with flammable process fluid, the electrode circuit must
be installed as intrinsically safe (Ex ia).
3.
Conduit entries must be installed to maintain a minimum
enclosure ingress rating of IP66.
4.
Unused conduit entries must use either used the Rosemount-
supplied blanking plugs, or blanking plugs certified in
accordance with the protection type.
K5 Explosion-Proof with Intrinsically Safe Electrodes
for Class I Division 1, Groups CD: T3...T6
Non-Incendive with Intrinsically Safe Electrodes
for Class I, Division 2, Groups ABCD: T3...T5
Dust-Ignition Proof for Class II/III, Division 1, Groups EFG: T2...T5
-29°C
Ta
60°C
Enclosure Type 4X, IP66/68 (IP68 remote mount only)
Install per drawing 08732-2062
Special Conditions for Safe Use (X):
1.
Units marked with "Warning: Electrostatic Charging Hazard"
may either use non-conductive paint thicker than 0.2 mm or
non-metallic labeling. Precautions shall be taken to avoid
ignition due to electrostatic charge on the enclosure.
2.
If used with flammable process fluid, or if installed in a Class I
Division I area, the electrode circuit must be installed as
intrinsically safe (Ex ia).
3.
Conduit entries must be installed to maintain a minimum
enclosure ingress rating of IP66.
4.
Unused conduit entries must use either used the Rosemount-
supplied blanking plugs, or blanking plugs certified in
accordance with the protection type.