3. Dimensions
468 363
56
4. Installation
16952
Based on the national constitu-
tion guidelines a general test
certificate concerning the evi-
dence of applicability of noise
behaviour is granted.
170
Dimensions in mm
96
100
The following regulations must be observed:
• e.g. VDE 0100
• EN 806
• Installation must comply with all statutory regulations, as well as those of the local
electricity and water supply companies.
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
Installation site
• Appliance must only be installed in frost-free rooms. Never expose appliance to
frost.
• The Appliance must be wall mounted and has to be installed with water connectors
downward or alternative transversely with water connections left.
• The appliance complies with protection type IP25 and may therefore be installed in
protection zone 1 according to VDE 0100 part 701 (IEC 60364-7).
• In order to avoid thermal losses, the distance between the instantaneous water
heater and the tap connection should be as small as possible.
• The appliance must be accessible for maintenance work.
• Plastic pipes may only be used if they conform to DIN 16893, Series 2.
• The specific resistance of the water must be at least 1100 Ω cm at 15 °C. The specific
resistance can be asked for with your water distribution company.
• Do not install the device in the immediate proximity of metal surfaces to allow a
reliable wireless connection and an optimal wireless range.
41
239
CLAGE
EN