2. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
EN
Chosen capacity / current
Nominal voltage
Electrical connection
Min. required cable size
Hot water (l/min)
2)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required spec. water resistance
Spec. electrical conductivity
Inlet temperature
Switch on – max. flow rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
Transmission and receiving frequency
range Wi-Fi
Transmission power Wi-Fi
Transmission and receiving frequency
range Bluetooth
Transmission power Bluetooth
Radiation
Transmission range
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013.
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Electronically controlled depending on the desired temperature and cold water temperature
18 kW /
16.2 kW /
26 A
400 V
4.0 mm
1)
9.2
6.8
in electrical connection from above.
2
DFX Next
18 kW..27 kW (26 A..39 A)
21 kW /
19 kW /
25 A
30 A
29 A
380 V
400 V
380 V
3~ / PE AC
4.0 mm
2
2
8.3
10.7
9.7
6.1
7.9
7.2
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90 mS/m
≤ 70 °C
1.5 l/min – automatic
0.08 bar at 1.5 l/min
20 – 60 °C [70 °C]
G ½ inch
4.5 kg
2.412 – 2.472 GHz (802.11 b/g/n)
≤ 100 mW
2.4 – 2.4385 GHz
≤ 8 mW
undirected
10 meter incl. barrier
40
A *
)
24 kW /
21.7 kW /
27 kW /
35 A
33 A
39 A
400 V
380 V
400 V
6.0 mm
2
12.3
11.1
13.8
9.0
8.2
10.2
®
3)
1.3 bar at 9.0 l/min
I
IP25
24.4 kW /
37 A
380 V
6.0 mm
2
12.5
9.2