Translation of the original instructions
Ammeter's needle gets over the
maximum scale whereas the switch
set up is into the minimum.
The fuse blows every time it is
replaced
The battery is boiling.
Sparks coming on battery terminals.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reporte
14
MULTICHARGE CT 48
The battery is deeply discharged.
Voltage error (12 -24V)
Your battery has elements in short
circuit.
Polarity reversal
Starting the vehicle
Current overconsumption on the
battery
The machine charges a battery that
its voltage is lower than the charger's
output nominal voltage.
The output voltage selection is not
consistent with the battery voltage.
Your battery has elements in short
circuit.
Polarity is reversed at the clamps
Hold the charge while selecting a low-
er charging speed in order to avoid
damaging the battery. Check that the
current decreases during the charge
and adjust the charging speed regular-
ly during the charge.
Check that the switch is on the right
setting (12 or 24V)
Battery damaged. Change the battery.
Connect the + clamp to the battery's
(+) and the + clamp to the battery's
(-).
Do not attempt to jump start when
the charger is connected.
Do not draw any of the battery's
current during the charge
Set up the output voltage switch on
correct battery voltage.
Set up the output voltage switch on
correct battery voltage.
The battery is damaged and must be
replaced.
Connect the clamps to the battery
terminal (black clamp to "-" and red
clamp to "+").
EN