Translation of the original instructions
POWER SUPPLY (I P.51)
SPOT EXPERT 230
This equipment is supplied with a 16 A CEE7/7 type socket and must only be used on a single-phase 230 V (50-60 Hz)
3-wire electrical installation with an earthed neutral.
SPOT EXPERT 400
400 V two phase power supply 50-60 Hz. Use of PH (1), PH 2 (2) and EARTH (PE). Circuit breaker 16A delayed D curve
or 16A fuses type aM.
NB : If the product trips the circuit breaker, please check that the correct fuse and an adequate circuit
breaker are being used.
PRODUCT SPECIFICATIONS
SPOT EXPERT
ELECTRIC SPECIFICATIONS
U
rated power supply voltage
1N
Frequency
U
rated no load voltage
20
Permanent power U
SP
Permanent supply current I
Maximal current of a permanent primary short circuit I
Maximal current of a secondary short circuit I
Permanent secondary current I
Type of welding current
THERMAL SPECIFICATIONS
Operating ambient temperature
Storage and transport operating ambient
OPERATING AND SETTINGS (III P.51)
1. Connect the machine to an appropriate power supply.
2. Connect the gun (or the guns) with the connectors.
The trigger gun has, in addition to the power connector, a trigger control connector. Connect the latter to
initiate using the trigger
3. Turn the breaker (1) to ON.
4. For the first use :
•
The indicators switch on for few seconds then the machine automatically switches in SYNERGIC mode (8) It indi-
cates :
- the tool (2) : set on 1 by defaut (star welding or use the hollow pulling clamp).
- the power level (3) : set on 2 by defaut (setting adapted for 0.8mm steel sheets).
•
To use the MANUAL mode (9), press on the button (10).
The SYNERGIC mode give to the user recommended factory settings for each tool used on a given sheet thic-
kness.
The MANUAL mode allows the user to choose his own types of settings, without the tool connected being taken
into account, by selecting the desired power and point time.
5. Depending the mode chosen, SYNERGIC or MANUAL, change the settings as follows :
- To change the tool, press on the arrows (5). - (Accessible in SYNERGIC mode only).
SPOT EXPERT 230 / 400
1p
1cc
2cc
2p
(ON switch on the front panel on the EXPERT 230)
EN
230
400
1~ 230 V
2 ~ 400 V
50/60 Hz
7.4 V
1.8 kVA
1.9 kVA
7.8 A
4.6 A
90 A
60 A
2 800 A
3200 A
270 A
250 A
De -10°C à +40°C
De -20°C à +55°C