9. START-UP
The charger must be used with a stabilised direct current voltage (11-18V=).
Never use the charger with another voltage as this will destroy the charger and
invalidate the warranty/guarantee!
Depending on the battery connected, a charge current of up to 10A is possible.
For this reason, the power supply chosen must be strong enough.
Connect the connection cable (12) to the power supply. Ensure correct polarity (plus/+ and
minus/-)! The red cable must be connected to the positive pole (plus/+), the black one with
the negative one (minus/-).
The charger emits a brief audio signal and the LC display is illuminated. The charger is
now on the main menu:
Example:
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
NiMH BATT
NiMH BATT
NiMH BATT
NiMH BATT
NiMH BATT
Please heed the following points before connecting/charging the battery:
• If you have not done so already, please read chapter 5 and 6 completely and
ensure that you have understood the information there.
• Do you know all of the information about your battery that you need to know?
Unknown or unlabelled batteries, the necessary values of which you do not
know, may not be connected/charged/discharged!
• Have you selected the correct charging program for the type of battery you
are using? Selecting the wrong settings will damage the charger and the
battery and present a risk of fire and explosion!
• Have you selected the appropriate charge current?
• Have you selected the correct voltage (e.g. for multiple-cell LiPo batteries)?
A dual-cell LiPo battery can, under certain circumstances, be connected in
parallel (3.7V) or in series (7.4V).
• Are all connector cables and plugs undamaged, do the plugs stay firmly in
the sockets? Worn-out plugs and damaged cables should be replaced.