All manuals and user guides at all-guides.com
• With the "INC" button, you access the next setting (or with the button "DEC" the previous
setting or return to the main menu with the button "TYPE/STOP".)
NiMH Sensitivity
NiMH Sensitivity
NiMH Sensitivity
NiMH Sensitivity
NiMH Sensitivity
D.Peak 10mV/Cell
D.Peak 10mV/Cell
D.Peak 10mV/Cell
D.Peak 10mV/Cell
D.Peak 10mV/Cell
Here you can set the sensitivity of the delta-U detection of NiMH battery (voltage differ-
ence in the delta-U charge procedure).
A value which is too high may overcharge the battery but if the value is too low, the
battery may not be completely charged.
Briefly press the button "ENTER/START". The voltage value then begins to flash.
With the buttons "INC" or "DEC", you can set the voltage value (5 to 20mV). If you select
"DEFAULT", the charger uses a voltage of 7mV.
Save the setting with the button "ENTER/START"; the voltage stops blinking.
• With the "INC" button, you access the next setting (or with the button "DEC" the previous
setting or return to the main menu with the button "TYPE/STOP".)
NiCd Sensitivity
NiCd Sensitivity
NiCd Sensitivity
NiCd Sensitivity
NiCd Sensitivity
D.Peak
D.Peak
D.Peak
D.Peak
D.Peak
Here you can set the sensitivity of the delta-U detection of NiCd batteries (voltage
difference in the delta-U charge procedure).
A value which is too high may overcharge the battery but if the value is too low, the
battery may not be completely charged.
Briefly press the button "ENTER/START". The voltage value then begins to flash.
With the buttons "INC" or "DEC", you can set the voltage value (5 to 20mV). If you select
"DEFAULT", the charger uses a voltage of 12mV.
Save the setting with the button "ENTER/START"; the voltage stops blinking.
Default
Default
Default
Default
Default
87