TABLE "B" LOGICS
Any modi cation of parameters/logics must be con rmed by pressing S2 > 5s
DIP
Logic
Transmitter
1
programming
2
BAR / 8K2
Photocell input
3
check
4
Edge input check
Photocells
5
during closing
6
Fast closing
Block pulses
7
during opening
8
3-step logic
Safety edge input
6
operation
7
Fast closing
Residential /
apartment
8
building
operation
26 -
ARES BT A 1000-1500
INSTALLATION MANUAL
Cross out
Default
Description
setting used
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
ON
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
ON
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input con gured as Bar 8k2. Input for resistive edge 8K2.
ON
The command reverses movement for 2 sec.
OFF
Input con gured as Bar, safety edge.
OFF
The command reverses movement for 2 sec.
ON
Enable safety check on the PHOT input
OFF
OFF
Safety check on PHOT input not enabled
ON
Enable safety check on the BAR input
OFF
OFF
Safety check on BAR input not enabled
In the event beam is broken, photocell operation is disabled during opening. During closing,
ON
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
OFF
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
Only active on FW < 3.03
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
OFF
Logic not enabled
ON
The start pulse has no e ect during opening.
OFF
OFF
The start pulse has e ect during opening.
Switches to 3-step logic; during closing, start
ON
reverses movement.
OFF
OFF
Switches to 4-step logic.
Only active on FW ≥ 3.03
ON
Safety edge with active reversal only when closing, when opening the movement stops
OFF
OFF
Safety edge with active reversal in both directions
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
OFF
Logic not enabled
Sets the automation type of operation:
ON
ON = Apartment building
OFF
OFF = Residential
Reaction to the START input (wired or radio):
CLOSED
WHILE CLOSING
OPEN
WHILE OPENING
AFTER STOP
Reaction to the OPEN input (wired):
OFF
CLOSED
WHILE CLOSING
OPEN
WHILE OPENING
AFTER STOP
Reaction to the PEDESTRIAN input (radio):
CLOSED
WHILE CLOSING
OPEN
WHILE OPENING
AFTER STOP
CLOSED
DURING CLOSING
DURING OPENING
AFTER STOP
Residential
Apartment building
Opens
Opens
Stops
Opens
Closes
Closes
STOPS + TCA
No e ect
Opens
Opens
Residential
Apartment building
Opens
Opens
Opens
Opens
No e ect
No e ect
Keeps it open
Keeps it open
Opens
Opens
Residential
Apartment building
Opens partially
Opens partially
Stops
Opens partially
Closes
Closes
STOPS + TCA
No e ect
Opens partially
Opens partially
3 step
4 step
opens
opens
stop
OPEN
closes
closes
stop +
stop +
TCA
TCA
opens
opens