3. Touch the timer display.
The timer symbol of the extractor unit lights up brightly.
4. Use the '+' or '-' key to set the desired delay time.
Countdown starts automatically.
The extractor unit switches off after the time that has been set.

Saturation of the odour filter

After 100 operating hours, the grease filter symbol is illuminated; it is necessary to perform
maintenance of the grease filter (see 'Maintenance/Cleaning the filters'). The grease filter saturation
indication is always enabled.
Saturation of the odour filter
By default the odour filter saturation indication is deactivated (when the extraction is operating in
ducted mode). Activate the odour filter saturation indication if the extraction unit is installed as a
recirculation application.
After 200 operating hours, a flashing 'C' will appear in the extractor unit display; it is necessary to
perform maintenance of the odour filter (see 'Maintenance/Cleaning the grid and filters').
Activation of the odour filter saturation indication
1. Touch the extraction key.
2. Again, touch and hold the extraction key for 5 seconds.
The odour filter symbol 'C' lights up intensely for 1 second.
Now the symbol 'C' is iluminated in the display when it is necessary to perform maintenance
of the odour filter.
Deactivation of the odour filter saturation indication
1. Touch the extraction key.
2. Again, touch and hold the extraction key for 5 seconds.
The odour filter symbol 'C' blinks twices.