3. General description
3.1. Use
The wastewater lifting plant SaniQ Plus above-ground in-
stallation promotes domestic wastewater, e.g. from sink,
shower or washing machine, from areas below the back
flow level, or from areas which slope to the next channel
connection are too low.
The version with the pump CH140WA also promotes
chemically aggressive clear water or wastewater, such
as salt water, from water softeners and condensate from
condensing boilers. For chemically aggressive media a
consultation is necessary because the resistance of the
pump materials must be checked.
3.2. Use types
The wastewater lifting plant is designed for the continu-
ous service of operating type S1.
3.3. Assembly
The lifting systems are made of a non-rotting water, gas
and odor-proof plastic container with a single-stage cen-
trifugal pump.
The container has one vertical inlet, four horizontal inlets
and a horizontal pressure outlet. Additionally, the con-
tainer includes an activated carbon filter to warrant odor
tightness and ventilation needs. The pressure outlet is
equipped with an integrated check valve.
The pump has a thermal switch, which switches off
the pump in case of overheating and that automatically
switches it on after cooling.
All manuals and user guides at all-guides.com
3.4. Functional description
The pumping medium passes through the various feed
streams into the container. There, it is collected until it
reaches a certain level and activates the float switch. This
turns off the pump automatically. Now the pumping me-
dium is being supplied by the pressure outlet above the
flood level of the public sewer.
Technical details
C140 WA
Power consumption
0,32 kW
Motor power
0,17 kW
Voltage
230V / 1Ph
Rotational speed
2900 U/min
Nominal current
1,4 A
Protection type
IPX8
Weight
7,0 kg
Tank volume
27 l
Effective volume
7 l
Permissible temperature of
35°C
medium
short term 60°C
CH140 WA
0,32 kW
0,17 kW
230V / 1Ph
2900 U/min
1,4 A
IPX8
7,0 kg
27 l
7 l
35°C
EngliSH | 19