Caution
Never operate the machine if the safety and monitor-
ing devices have been removed or damage, or if they
do not work.

2.8. Pumped fluids

Each pumped fluid differs in regard to composition, cor-
rosiveness, abrasiveness, TS content and many other
aspects. Generally, our products can be used for many
applications. For more precise details, see chapter 3, the
machine data sheet and the order confirmation. It should
be remembered that if the density, viscosity or the gener-
al composition change, this can also alter many parame-
ters of the product.
Different materials and impeller shapes are required for
different pumped fluids. The more exact your specifica-
tions on your order, the more exactly we can modify our
product to meet your requirements. If the area of applica-
tion and/or the pumped fluid change, we will be happy to
offer supportive advice.
When switching the product into another pumped fluid,
observe the following points:
Products which have been operated in sewage or
waste water must be thoroughly cleaned with pure
water or drinking water before use.
Products which have pumped fluids which are haz-
ardous to health must always be decontaminated be-
fore changing to a new fluid. Also clarify whether the
product may be used in a different pumped fluid.
With products which have been operated with a lu-
bricant or cooling fluid (such as oil), this can escape
into the pumped fluid if the mechanical shaft seal is
defective.
Danger - explosive fluids!
It is absolutely prohibited to pump explosive liquids
(e.g. gasoline, kerosene, etc.). The products are not
designed for these liquids!

2.9. Sound Pressure

Depending on the size and power (kW), the pump has a
sound pressure of about 40dB (A) to 70dB (A) during op-
eration. However, the actual sound pressure depends on
several factors. These are, for example, the type of instal-
lation and set-up, mounting of accessories, piping, operat-
ing point, immersion depth, and much more.

3. General description

3.1. Use

Pumps in this series are single-stage, transportable
centrifugal pumps that are suitable for conveying clean
or lightly contaminated water. They can be used for both
transportable and stationary operation. They may be
installed free-standing on a firm supporting surface.
These pumps are not suitable for conveying liquids
containing seriously abrasive fractions (e.g. sand,
gravel or stones).
Their areas of application include private sewage disposal
in cellar rooms, keeping pits and spaces dry. These pumps
are suitable for transportable and stationary operation.
They may be installed free-standing on a firm supporting
surface.
Their use in slurp operation is permitted.
The temperature of the conveyed liquid may go up to
35°C, or briefly up to a maximum of 60°C. The maximum
density of the conveyed liquid is 1100 kg/m³ and its pH
value may be 6 - 8.

3.2. Types of use

The pumps are designed for the S2 (short-time duty) and
S3 (intermittent duty) mode of operation. You can find
precise data in the Table in section 3.3.1 Motor.

3.3. Construction

The fully submersible unit consists of the motor, the pump
housing and the appropriate blade wheel. All important
components are generously dimensioned.
No.
Description
1
Non - return valve
2
Cable inlet
3
Handle
4
Motor housing
5
Suction side
6
Float switch
ENGLISH | 23