15.2 Special connection conditions
• The
product
fulfils
61000-3-11 and is subject to special connection re-
quirements. This means that use at any freely select-
able connection points is not permitted.
• The product can cause temporary voltage fluctua-
tions in unfavourable mains conditions.
• The product is intended exclusively for use at con-
nection points which
a) do not exceed a maximum permitted mains im-
pedance "Z" (Zmax. = 0.443 Ω), or
b) have a continuous current carrying capacity of the
mains of at least 100 A per phase.
• As the user, you are required to ensure that the con-
nection point at which you wish to operate the prod-
uct fulfils one of the requirements mentioned, a) or
b). If necessary, consult with your energy supplier in
this regard.
15.3 Damaged electrical connection
cables
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are passed
through windows or doors,
• Kinks where the connection cable has been improp-
erly fastened or routed,
• Places where the connection cables have been cut
due to being driven over,
• Insulation damage due to being ripped out of the
wall socket,
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be
used and are life-threatening due to the insulation dam-
age.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the appli-
cable VDE and DIN provisions. Only use connection ca-
bles with the same designation "H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
Safety information for replacing damaged or
defective mains connection cables
Connection type X
If the mains connection cable of this product is dam-
aged, it must be replaced by a specially prepared mains
connection cable which can be obtained from the man-
ufacturer or its service department.
the
requirements
of
EN
15.4 AC motor
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
• The mains voltage must be 220 V - 240V~.
• Extension cables up to 25 m long must have a cross-
section of 1.5 mm².
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Motor data - type plate
16 Repair & ordering spare parts
After repairs or maintenance, make sure that all safety-
related parts are installed and are in perfect condition.
All parts which may cause injury must be kept where
they are inaccessible to children or others.
ATTENTION
According to the German Product Liability Act, no lia-
bility is accepted for damage caused by improper re-
pairs or by not using original spare parts.
Such work should be performed by a customer service
centre or an authorised specialists. The same applies
to accessory parts.
Connections and repairs
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
16.1 Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consumables.
Wearing parts*: carbon brushes, saw blade, table inlay,
saw dust bag
* = not included in the scope of delivery!