• Never point the laser beam towards reflecting sur-
faces and persons or animals. Even a laser beam
with a low output can cause damage to the eyes.
CAUTION
Methods other than those specified here
can result in dangerous radiation expo-
sure.
• Never open the laser module. Unexpected exposure
to the beam can occur.
• The laser may not be replaced with a different type
of laser.
• Repairs of the laser may only be carried out by the
laser manufacturer or an authorised representative.
6.9
Residual risks
The product has been built according to state-of-
the-art and the recognised technical safety rules.
However, individual residual risks can arise during
operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety Instruc-
tions" and the "Intended Use" together with the oper-
ating manual as a whole are observed.
• Do not load the product unnecessarily: excessive
pressure when sawing will quickly damage the saw
blade, which results in reduced output of the product
in the processing and in cut precision.
• When cutting plastic material, please always use
clamps: the parts which should be cut must always
be fixed between the clamps.
• Avoid accidental start-up of the product: when in-
serting the plug into the socket, do not press the on/
off switch.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that
your product provides optimum performance.
• Keep your hands away from the working area when
the product is in operation.
• Before performing setting or maintenance work, re-
lease the on/off switch and pull out the mains plug.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or pas-
sive medical implants under certain circumstances. In
order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
8
|
GB / IE / NI
7
Technical data
AC motor
Nominal power S1
Operating mode
Idle speed n
0
Carbide saw blade
Number of teeth
Maximum tooth width of
the saw blade
Pivot range
Mitre cut
Saw width at 0°
Saw width at 45°
Saw width at 2 x 45°
(double mitre cut)
Protection class
Weight
Laser class
Laser wavelength
Power of laser
Operating mode S6
Uninterrupted periodic operation. The mode comprises
of a start-up period, a time with constant load and an
idle time. The operating time is 10 mins, the relative du-
ty cycle is 25% of the operating time.
The workpiece must have a minimum height of 3
mm and a minimum width of 10 mm. Make sure
that the workpiece is always secured with the
clamping device.
Noise data
WARNING
Noise can have serious effects on your health. If the
machine noise exceeds 85 dB, please wear suitable
hearing protection for you and persons in the vicinity.
The noise and vibration values have been determined in
accordance with EN 62841-1.
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
wA
Uncertainty K
wA
The specified noise emission values have been measured
in accordance with a standardised test procedure and can
be used to compare one power tool with another.
The specified device emissions values can also be used
for an initial estimation of the load.
220 - 240 V~
50 Hz
1700 Watts
S6 25%* 2000 W
4800 rpm
ø 210 x ø 30 x 2.6 mm
24
3 mm
-47 ° / 0° / +47 °
0° to 45° to the left
340 x 65 mm
240 x 65 mm
240 x 38 mm
II /
approx. 10.8 kg
2
650 nm
< 1 mW
90.5 dB
3 dB
103.5 dB
3 dB