Beschikbare talen

en Installation instructions
Notes
¡ If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
13.10 Installation
Checking the wall
Check whether the wall is vertical and has sufficient
1.
load-bearing capacity.
The maximum weight of the appliance is 40 kg.
2.
Drill the hole depth in accordance with the length of
the screws.
Use the enclosed screws and wall plugs.
3.
The enclosed screws and wall plugs are suitable for
use with solid brickwork. Use suitable fixing material
for other structures, e.g. plasterboard, porous con-
crete, poroton bricks.
Preparing the wall
Note: Depending on the design, holes must be placed
differently. Before installing, pay attention to the design
of the extractor hood.
Ensure that there are no electrical wires, gas pipes
1.
or water pipes in the area where holes are to be
drilled.
Mark a vertical centre line on the wall from the ceil-
2.
ing to the lower edge of the appliance.
Mark the positions for the screws and the contour of
3.
the attachment area.
Drill 8 mm diameter holes to a depth of 80 mm and
4.
press in the wall plugs flush with the wall.
Screw on the retaining bracket for the flue duct.
5.
Screw in 2 securing screws with washers to approx.
6.
5 mm.
26
Installing the appliance
Attach and align the appliance.
1.
Mark the hole for the safety screw.
2.
Remove the appliance again.
3.
4.
Drill an 8 mm diameter hole to a depth of 80 mm
for the safety screw and press the wall plug flush
into the wall.
Remove the protective film from the rear.
5.
Once the appliance is installed, fully remove the
protective film.
Attach the appliance.
6.
Screw in the safety screw with the washer.
7.
8.
Establish the electrical connection.
Piping
Note: If you are using an aluminium pipe, smooth the
connection area beforehand.
We recommend the piping with an exhaust air pipe dia-
meter of 150 mm.
Establishing the exhaust air connection (exhaust
pipe, 150 mm diameter)
Secure the exhaust pipe to the air pipe connector.
1.
Establish the connection to the exhaust air opening.
2.
Seal the joints.
3.
Establishing the exhaust air connection (exhaust
pipe, 120 mm diameter)
Secure the reducing connector to the air-pipe con-
1.
nector.
Secure the exhaust air pipe to the reducing con-
2.
nector.
Seal the joints.
3.
Installing the flue duct
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.