Maintenance and care
TAS-UNI
V4
6
Maintenance and care
6.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
Take care that for all maintenance services the device is completely shut down!!
Attention
MECHNICAL
Service interval
First inspection after
25 operating hours
All 50 operating hours
Minimum 1x per year
(at rough conditions shorten
the interval)
Maintenance work
●
Control and tighten all screws and connection.
(The implementation is only allowed by an expert).
●
Tighten all screws and connection (Take care that the tightening torques
according to the property class of the screws are observed).
●
Check all joints, bolts, guidance's and gears for correct function, if necessary
adjust or replace it.
●
Check all Grippers ( if available) for signs of wear.
●
Grease all slidings ( if available) when the device is in opened position with a
spatula.
●
Check of all the suspension parts, bolts and straps. Check for corrosion and
safety by an expert.
12/06/18