Installation and Operation
TAS-UNI
V4
4.1.3
Adjustment pan profile
Loosen both nuts (2) on the inner side at the TAS-DP. Figure 7
Adjust the slope (e.g. 1%) with the both nuts (3) on the inner side at the TAS-DP. Figure 8
Slope (e.g. 1%) is viewable and adjustable on the scale (4) and indicator (5). Figure 9
1 scale line on the scale (4)
The indicated slope (%) on the scale is only for orientation.
The actually slope (%) must be measured again unconditional on the facing bedding sand!
See Figure B und B1 on the following pages.
Figure 7
(2)
Measure the outer dimension at the TAS-DP (1) with a qualified measuring tool (6) e.g. yard stick (or slide gauge). These
measure must be equal at the front side and back side (see ).
Figure 10 and Figure 11.
Tighten both nuts again (tight) on the inner side at the TAS-DP. Figure 12
Figure 10
≙
0,5 % slope. Figure 9
(2)
(1)
(6)
Figure 8
(3)
(3)
Figure 11
(6)
Figure 9
(5)
Figure 12
12/06/18
10 / 18
(4)