Download Inhoudsopgave Inhoud Print deze pagina

Adjustment Pan Profile - probst TAS-UNI Bedrijfshandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Installation and Operation
TAS-UNI
V4
4.1.3

Adjustment pan profile

Loosen both nuts (2) on the inner side at the TAS-DP.  Figure 7
Adjust the slope (e.g. 1%) with the both nuts (3) on the inner side at the TAS-DP.  Figure 8
Slope (e.g. 1%) is viewable and adjustable on the scale (4) and indicator (5).  Figure 9
1 scale line on the scale (4)
The indicated slope (%) on the scale is only for orientation.
The actually slope (%) must be measured again unconditional on the facing bedding sand!
See Figure B und B1 on the following pages.
Figure 7
(2)
Measure the outer dimension at the TAS-DP (1) with a qualified measuring tool (6) e.g. yard stick (or slide gauge). These
measure must be equal at the front side and back side (see ).
 Figure 10 and Figure 11.
Tighten both nuts again (tight) on the inner side at the TAS-DP.  Figure 12
Figure 10
0,5 % slope.  Figure 9
(2)
(1)
(6)
Figure 8
(3)
(3)
Figure 11
(6)
Figure 9
(5)
Figure 12
12/06/18
10 / 18
(4)

Advertenties

Inhoudsopgave
loading

Inhoudsopgave