WARNING
Risk of explosion!
If the CatEx sensor is exposed to hydrogen and low
temperatures (< -10 °C) for a long time (> 1 h), measured
values that are too low may be displayed. This also applies if
hydrogen is being measured but the measured gas set is not
hydrogen.
► The CatEx sensor should be set to the measured gas
"hydrogen"for regular and planned measurements of
hydrogen. Measuring tasks which last less than 30 min.
are not affected by this.
Increased hydrogen concentrations within the measuring
range of the DrägerSensor XXS H
may trigger false alarms by additively influencing Dräger
sensors XXS H
S and XXS CO, XXS H
2
LC, and negatively influencing DrägerSensor XXS O
XXS O
PR.
2
2
Conventions in this document
2.1
Meaning of the warning notes
The following warning notes are used in this document to
notify users of possible dangers. The meanings of the warning
notes are defined as follows:
Alert icon Signal word
WARNING
CAUTION
NOTICE
2.2
Trademarks
Trademark
Trademark owner
Dräger
®
X-am
Bluetooth SIG, Inc.
®
Bluetooth
The following webpage lists the countries in which Dräger's
trademarks are registered: www.draeger.com/trademarks.
The trademarks mentioned are only registered in certain
countries and not necessarily in the country in which this
material was published.
Instructions for use
|
X-am
HC and CatEx sensor
2
S-LC and XXS CO-
2
2
Consequences in case of
nonobservance
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in death or serious
injury.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in physical injury. It
may also be used to alert
against unsafe practices.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in damage to the
product or environment.
®
®
2600 / X-am
2800 / X-am
2.3
Abbreviations
Abbreviation
A1
A2
PID
STEL
TWA
and
3
Description
3.1
Product overview
1
2a
2
7
6
OK
Graphic A
1 Gas inlet
2 Alarm LED
2
D-Light
a
3 Horn
4
key
OK
5 Power pack
6
key
7 Display
®
5800
Conventions in this document
Explanation
Pre-alarm
Main alarm
Photoionization detector
Short time exposure limit, threshold of an
exposition over a short period of time (gen-
erally 15 minutes).
Time weighted average, average shift val-
ues are generally limited to eight hours
exposure per day per workplace for 5 days
a week during a work lifetime. Observe the
national definition of the occupational
exposure limit.
8
2
9
3
10
4
12
5
11
8 IR interface
9 Fastening clip
1
Name plate
0
1
Charging contacts
1
1
Measured gas display
2
1
Measuring value display
3
1
Special symbols
4
1
Allen key
5
(2 mm; alternative: Torx
T8)
|
en