Accessories

Filter gravel, fine
Order No. 6.272-001.0 (Grain size 04,...0.8
mm) in 25 kg sack
Filter gravel, medium
Order No. 6.272-003.0 (Grain size 1...2
mm) in 25 kg sack
Needed for one fiter filling
Filter gravel,
fine 6.272.-
001.0
WRP
7 sacks
8000
WRP
10 sacks
16000
Accessories
Order number
Recycled water tank
2.642-720.0
Additional tank
2.642-930.0
Upgrade kit tank con-
4.640-401.0
nection, 2 tanks
Upgrade kit tank con-
4.640-402.0
nection, 3 tanks
Ventilation
2.641-510.0
Overflow
2.641-995.0
Immersion pump
2.642-037.0
WRP 8000
Immersion pump
2.642-038.0
WRP 16000
Stand for switch cabi-
2.642-116.0
net
Conductivity meas-
2.642-765.0
urement
Fresh water supply
2.642-113.0
WRP 8000
Fresh water supply
2.642-114.0
WRP 16000
22
Installing the unit (only for ex-
Notice
The equipment may only be installed by an
mechanic of Kärcher
or an from Kärcher authorized individu-
al
Preparing the installation place
The following requirements are necessary
Filter gravel,
in order to install the equipment:
medium 6.272.-
frost-free room with adequate ventila-
003.0
tion and exhausts
2 sacks
Floor path for collecting sludge
Pipes and underground construction as
3 sacks
per drawings 0.089-491.0 and 0.089-
492.0.
Water and electrical connection: see
"Technical data"
horizontal, even foundation
Protect the plant against direct sunlight
and spray water
Sufficiently illuminate the installation
site
The floor must be freely accessible.
Unpack the equpiment and dispose of the
packing material properly.
The water installation depends on the spe-
cific conditions of the existing plant compo-
nents such as
Type and model of washing unit
Type and models of building-side com-
ponents (sludge collector, pump basin,
etc.)
Nominal widtht, lengths and type of
channels
Hence, the water installation must be car-
ried out according to the specific project
documents.
Danger
Risk of injury on account of tripping and fall-
ing.
Lay the hoses of the plant in such a way
that they do not pose a risk for tripping and
falling.
Danger
Risk of electrical voltage. All electrical in-
stallations may only be done by an electri-
cian according to the local regulations.
The plant must be secured through a wrong
current protection switch with a triggering
current lesser than or equal to 30 mA.
The appliance may only be connected
to alternating current.
The appliance may only be connected
to an electrical supply which has been
installed by an electrician in accord-
ance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.
perts)
Unpack the equipment
Water installation
Electrical connection
EN
10
-
EC Declaration of Conformity
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
Product:
Water treatment plant
Type:
1.217-xxx
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2004/108/EC
Applied harmonized standards
EN 60204–1
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 1997+A1: 2001+A2: 2008
EN 61000–3–2: 2006+A1: 2009+A2: 2009
EN 61000–3–3: 2008
EN 62233: 2008
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
CEO
Head of Approbation
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2014/01/01

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Wrp 16000

Inhoudsopgave