Fault
Possible cause
Water in the recy-
WRP was switched off during the night or
cled water tank has
over the weekend
a bad odour
none or very poor circulation, very little
ventilation
Continuous flow
Float switch, control or fresh water sole-
sound
noid valve defective
Immersion pump is
Water level in the pump basis is too low
not functioning
Float switch S7 defective
Control head of multi-channel valve is de-
fective
Controls are defective
Filter output is too
Shutoff valve recycled water closed
low
Gravel filter is blocked
Immersion pump is blocked, defective
Pipe or valve is leaky, defective, blocked
Fresh water con-
Float switch S9 is defective.
sumption is too high
Conductivity sensor (option) is defective or
contaminated.
Fresh water solenoid defective
Transport
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Only transport the gravel filter when
empty (gravel fill removed).
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Storage
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
Only store the gravel filter when empty
(gravel fill removed).
Remedy
WRP must be ON continuously
Turn the rotary switch of the circulation pump to
position "III".
Check if the circulation valve is open.
Check pipes for dirt and damage; clean or replace
them as required
Check the ventilation, the ventilator must clearly
bubble in the pump basin.
Check, repair or replace the concerned compo-
nent
Washing system runs with fresh water until level
S15 top is reached. Find the cause.
Check the float switch; clean, repair or replace it
as required
Repair control head
Check, repair or replace controls
Open the shutoff valve recycled water.
Backwash gravel filter or change the gravel. If the
fault recurs, call customer service.
Clean, repair, replace immersion pump
Check pipes and valves; clean, repair or replace
as required
Replace
Check; clean, replace, if required.
Check the fresh water solenoid valve, replace if
required
EN
9
-
By whom
Operator
Operator
Operator, Cus-
tomer Service
Operator, Cus-
tomer Service
Operator, Cus-
tomer Service
Customer Ser-
vice
Operator, Cus-
tomer Service
Customer Ser-
vice
Customer Ser-
vice
Operator
Operator, Cus-
tomer Service
Operator, Cus-
tomer Service
Operator, Cus-
tomer Service
Customer Ser-
vice
Customer Ser-
vice
Customer Ser-
vice