Monitoring and regulating equipment
Float switch in the recycled water tank
Floater switch in the pump basin
* S5 optional
Immersion pump
Motor output
Voltage
Power consumption
Flow rate at approx. 0.1 MPa (1 bar), approx.
Pressure
Entire unit
Filter capacity
Voltage
Frequency
Weight
Width
Depth
Height
Maintenance and care
Maintenance instructions
The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggessted by him, such as
parts and wearing parts,
–
accessories parts,
–
operating materials,
–
cleaning agents.
–
18
S7 up
Recycled water tank full. Filling process is stopped.
S7 down
Recycled water tank is filled.
Delay 120 seconds.
S9 up
Switching off the fresh water supply. Indicator lamp "Fresh water supply" lights up yel-
low.
S9 down
Switching on the fresh water supply. Indicator lamp "Fresh water supply" lights up yel-
low.
S11 up
Dry run protection for washing system not active, no error message.
S11 down
Dry run protection for washing system active, error message on the washing system.
S5 top*
Pump basin overfilled. Starting the disposal via the recycled water tank into the chan-
nel
S5 bottom*
Pump basin is not overfilled, normal system operation.
S14 top
Pump basin full (with option salt water exfiltration).
S14 bottom
No function / switch point is not used
S15 top
Pump basin is not empty, normal system operation.
S15 bottom
Pump basin empty, dry run protection of immersion pump active, no filtration, no re-
flushing possible. System runs on fresh water.
Technical specifications
Danger
Risk of accident while working on the unit.
During all tasks
First switch-on in voltage-less state,
switch off the emergency stop switch
and secure it against being switched on
again.
Shut off water supply.
Who may perform maintenance?
Operator
–
Work designated with the sign "Opera-
tor" may only be carried out by persons
who have been instructed in the safe
W
V
A
m
/h
3
MPa (bar)
m
/h
3
V
Hz
kg
mm
mm
mm
EN
6
-
WRP 8000
1.217-151.0
1300
230/1~
5,9
8
max. 0.14 (1.4) max. 0.16 (1.6)
max. 10
230/1~
50
280
700
620
1600
operation and maintenance on washing
systems with recycling unit.
Customer Service
–
Work designated with the sign "Cus-
tomer Service" may only be done by the
fitters of Kärcher Customer Service.
Maintenance contract
In order to guarantee a reliable operation
og the equipment, we success, you signed
a maintenance agreement. Please refer to
you local Kärcher service department.
WRP 16000
1.217-152.0
1700
8,5
16
max. 20
390
900
780