4 .8
Configuring multiple control interfaces
Up to four control interfaces can be
configured (Group Code A, B, C or D).
Use one group code per control inter-
face.
1
10 seconds
1. Put the control interface in configuration mode.
• Push the joystick to the right and press and hold the 'ON/OFF' but-
ton for 10 seconds.
2
1 x
didahdi ( . − . )
2. Press the 'ON/OFF' button once .
You will hear the signal, di-dah-di ( . - . ).
Now the control interface is in configura-
tion mode.
n
ote
If a different combination of audible
signals sounds, first restore the factory
settings (see 4 .6) and start configuring
the control interfaces again (see 4 .8) .
4 .9
Malfunctions
Each malfunction has its own error code. Error codes are indicated by
sound signals.
When a malfunction occurs, you will first hear di-dah-di-di-dah (. - . . .).
Then, after a few seconds, the error code is transmitted by means of
sound signals (beeps). The number of beeps represents the number
of the fault code.
Example: if the bow thruster has overheated, you will first hear (. - - .
. .), then (- - - -). Thus: error code 4. This error code is repeated every
few seconds.
Accept the error message and end the audible signal by briefly press-
ing the "ON/OFF" button once. The error message is now temporarily
deferred.
Installation manual BOWPRO control interface CANVXCJP
On EVERY additional control interface, perform the following ac-
2
tions in the order indicated:
3
1
Switch off the control interface, see 4.4, and wait 5 seconds before
starting the configuration procedure below.
dididididididid ( . . . . . . )
seconds
6
For the first 6 seconds, the buzzer continuously gives a signal dididid-
ididi..... (. . . . . . ), keep pressing the 'ON/OFF' button. After 10 seconds,
the buzzer gives the signal dididididah ( . . . . - ). Release the button.
3
OR
3. Move the joystick left or right to set the
group code of the control interface.
The number of audible signals indicate
the group code of the control interface.
Group code
Audible signal
A
dah (-)
B
dah-dah (- -)
C
dah-dah-dah (- - -)
D
dah-dah-dah-dah (- - - -)
After accepting the error message, resolve the reported mal-
function as soon as possible!
Malfunction
Bow or stern thruster overheated
Bow or stern thruster overloaded
Bow or stern thruster limited
Bow or stern thruster supply voltage low
Supply voltage VCAN low (< 10 V)
Supply voltage VCAN outside operating range
(<8 V or > 15 V)
Joystick broken or off-centre
No CAN communication
dididididah ( . . . . − )
seconds
Configuration mode
4
4
4. Press the 'ON/OFF' button once to con-
firm the setting.
n
ote
ENGLISH
1 x
Error code
4
1
6
7
8
9
10
11
13
021004.11