11.10 Continuity test
Make sure that all objects that you wish to measure (including circuit com-
ponents, circuits and component parts) are disconnected and discharged.
Turn the multimeter on and select

measurement mode
Press the "SELECT" button once

to switch to continuity test mode.
The continuity test symbol and the
Ω symbol appear on the display.
Press the key again to switch to the
next measuring mode.
Insert the red test lead into the Ω

measurement socket, the black
test lead into the COM measure-
ment socket.
If the measured resistance is equal

to or less than 50 Ω, the multimeter
will beep to indicate continuity. The
beeps stop when the resistance ex-
ceeds 50 Ω. The continuity test measures resistances of up to 600 Ω.
"OL" (overload) indicates that the measuring range has been exceeded or that

the circuit is broken.
After measuring, remove the test leads from the measured object and turn the

multimeter off.