When taking a resistance measurement, make sure that the points that come
into contact with the probe tips are free from dirt, oil, solder and other impuri-
ties. These substances may distort the result.
The "REL" button only works when a measurement is displayed. It cannot be
used when "OL" is displayed.
11.9 Diode test
Make sure that all objects that you wish to measure (including circuit com-
ponents, circuits and component parts) are disconnected and discharged.
Turn the multimeter on and select

the measurement mode
Press the "SELECT" button twice

to switch to diode test mode. The
diode symbol and "V" appear on
the display. Press the button again
to switch to the next measurement
mode.
Insert the red test lead into the Ω

measurement socket, the black
test lead into the COM measure-
ment socket.
Check the measuring leads for

continuity by connecting both
measuring probes to one another.
A value of approx. 0.000 V should
be shown.
Connect the two test probes to the object that you want to measure (diode).

Connect the red test lead to the anode (+) and the black test lead to the cathode
(-).
The continuity voltage ("UF") will be shown in Volts (V). "OL" indicates that the

diode is reverse-biased (UR) or defective (interrupted). Try taking the measure-
ment again with the opposite polarity.
After measuring, remove the test leads from the measured object and turn the

multimeter off.
.