Troubleshooting
Fault
No output voltage at "INV.
AC OUTPUT" and "AC OUT-
PUT" and no charging cur-
rent; no LED lights up
No output voltage, "Alarm"
LED lights up red, display
shows "Overload Alert"
No output voltage, "Alarm"
LED lights up red, display
shows "UV Alert"
No output voltage, "Inverter"
LED lights up red, display
shows "OLP Shutdown"
No output voltage, "Inverter"
LED lights up red, display
shows "OLP Shutdown"
No output voltage, "Inverter"
LED lights up red, display
shows "UVP Shutdown"
EN
Cause
The device is switched off
The device is defective
No contact to the battery
Battery discharged
Battery defective
Defective fuse (in the device or
the vehicle)
The device is at 100% load
Battery voltage too low
Short circuit
Incorrect wiring
Overload
DC overvoltage
DC undervoltage
Troubleshooting
Remedy
Check the main switch
Replace the device
Check the contact and cables
Switch on the ignition if nec-
essary
Charge the battery
Replace the battery
Replace the fuse with one of
the same rating
Reduce the load (switch off
consumer units)
Switch off the device and on
again
Charge the battery
Check the 230 V cable
Reduce the load (switch off
consumer units)
Switch off the device and on
again
Reduce the battery voltage or
replace the battery
Check the cable
Charge the battery
99