_CombiPower_IA_DE-IT.book Seite 98 Freitag, 21. Oktober 2011 8:10 20
Configuring the device with the remote control
"Charge Parameter" menu (output parameters)
Parameter
Explanation
Ibat Setup
Determines the charging
current.
Second
Determines whether the
charger
5 A/2.5 A charger is switched
on or off.
Max. Bulk
Determines how long the battery
timer
is charges in the I phase (bulk).
Battery type Specifies the battery type.
Standard = standard batteries
(Battery type I)
Acid = acid batteries (battery
type II)
GelAGM = Gel and AGM batter-
ies (battery type III)
Spiral = batteries with spiral cells
(battery type III)
Customer = customer values
(battery type IV; according to
manufacturer's recommenda-
tions)
Information on the correspond-
ing charging voltage is stored in
the device.
I phase (bulk) charging
voltage
U0 phase (absorption)
charging voltage
U phase (floating) charging
voltage
98
Battery type I
Battery type II
12 V
24 V
12 V
14,4 V
28,8 V
14,4 V
14,4 V
28,8 V
14,25 V
13,5 V
27,0 V
13,8 V
Value range
CombiPower 2012:
20 – 100 A
CombiPower 2024:
10 – 50 A
ON
OFF
8 – 18 h
Standard
Acid
GelAGM/Spiral
Customer
Battery type III
24 V
12 V
24 V
28,8 V
14,7 V
29,6 V
28,5 V
14,25 V
28,5 V
27.6 V
13.6 V
27,2 V
CombiPower
Default
50 A
25 A
ON
8 h
Standard
Battery type IV
(Customer)
12 V
24 V
14 – 15 V 28 – 30 V
14 – 15 V 28 – 30 V
13 – 14 V 26 – 28 V