_CombiPower_IA_DE-IT.book Seite 71 Freitag, 21. Oktober 2011 8:10 20
CombiPower
No. in
fig. 4,
Symbol
page 4
11
–
12
–
13
–
EN
Explanation/function
Jumper for activating or deactivating an external
switch:
Jumper open: external switch function
deactivated
Jumper inserted (factory setting): external switch
function activated
4-pin plug
PIN 1: ALM (alarm- function)
not currently activated
PIN 2: CTL
Depending on the jumper (fig. 4 11, page 4) the
device can be forcibly switched on or off with a
positive signal.
Jumper open:
CTL input voltage 5 – 60 Vg = ON
CTL input voltage 0 Vg = OFF
Jumper closed:
CTL input voltage 5 – 60 Vg = OFF
CTL input voltage 0 Vg = ON
PIN 3: –ENB, PIN 4: –VCC
The device can be switched on and off using
these pins. No external voltage is required for
this. –ENB is connected via a switch to –VCC
(–VCC may not be connected to the negative
terminal of the battery.)
See fig. 6, page 5:
Switch closed = device ON
Switch open = device OFF
Note: If the device is switched on using this
function, it can be be switched off with the main
switch only.
Socket for remote control connection cable
Technical description
71