Technical description
6.8
Enabling functions
The device supports the functions described below.
Power sharing function
If the load from the connected consumer devices and the battery charging
current is higher than the connected 230 V power source, the fuse of the
power source would normally blow. In power sharing mode, the device
reduces the battery charging current and thus increases the power available
for connected consumers.
The power sharing level (current at the 230 V input) can be configured using
the remote control. If must be adapted to the fuse of the power source. For
example, if it has a 10 A fuse, the power sharing level must also be 10 A.