Operation
Automatic mode active
Manual mode active. The connected drive was operated manually (with the
arrow keys) or the
deactivated and the awning or Venetian blind is not controlled according to
brightness or temperature. The safety functions 'Rain alarm' and 'Wind alarm'
remain active. The controller remains in Manual mode until it is switched to
Automatic mode with the
Rain alarm. Outdoor awnings are retracted, manual operation is barred. The
rain alarm function can be activated and deactivated in the Automatic settings
(e.g. for indoor awnings or Venetian blinds).
Wind alarm. Outdoor awnings or Venetian blinds are retracted, manual
operation is barred. The wind alarm function can be activated and deactivated
in the Automatic settings (e.g. for indoor awnings or Venetian blinds).
Display of Brightness and Wind Velocity
Press the SET key once briefly while the temperature is displayed to display the current
brightness (in kilolux, kLux) and wind velocity (in metres per second, m/s). The values
are refreshed every 4 seconds.
Note: The wind velocity is not correctly displayed during the first approx. 90 seconds
after the power is restored to the weather station (e.g. after a power failure or during
commissioning). Manual operation is therefore barred during this period if the wind
alarm is active.
Pressing SET again briefly recalls the temperature display (or the central command
display, see next section). The temperature is also displayed again automatically after
approx. 60 seconds.
key was pressed. The automatic functions are thus
key.