i
Operation
GB
Manual Operation
Manual control, presetting of the automatic functions and basic setting of the connected
sunshade are performed with the keys on the operating unit.
Up
Stop
Down
The connected awning or Venetian blind can be operated by hand using the keys
,
and
. The arrow keys have an automatic timer function. Pressing the keys briefly
(less than 1 second) allows the awning or Venetian blind to be exactly positioned. If the
key is held depressed for longer than 1 second, the drive automatically runs up to the
end position. Pressing
stops the drive.
If the rain or wind alarm are active, manual operation is barred.
Manual/Automatic
The key
switches back and forth between Automatic mode (display
) and
Manual mode (display
). If the controller is operated manually via the keys
,
or
, it is then in Manual mode. The automatic functions are then deactivated and the
awning or Venetian blind is not controlled according to brightness or temperature. The
controller can be switched back to Automatic mode (display
) with the
key.
Pressing key SET briefly calls up the display of brightness and wind velocity.
Holding the key depressed calls up the setting mode for the automatic functions and
the basic setting. For further details, see section „Setting the Automatic Functions" or
„Basic Setting".
146