Installation of the Weather Station and Connection of the Drive
1
Cable connection to the precipitation sensor in the housing cover.
2
Drive connections (spring-loaded terminal, PE / N / Up / Down), suitable
for solid conductor up to 1.5 mm² or fine-wire conductor.
3
Opening for drive cable.
4
Power supply connections (230 V AC, spring-loaded terminal, L1 / N / PE),
suitable for solid conductor up to 1.5 mm² or fine-wire conductor.
5
Opening for power supply cable.
6
Fine fuse 6.3 A.
7
Programming LED. During normal operation, this LED indicates the reception of
a valid data packet by flashing briefly.
8
Programming button for teaching-in the radio link to the operating unit.
Connection of the Power Supply and Drive
The drive of the awning or Venetian blind is connected to the weather station. Several
drives can be connected in parallel. When connecting motors in parallel, check whether
a group control relay is prescribed by the motor manufacturer. Group control relays
can be sourced from Rademacher.
If motors are connected in parallel that are not suitable for this, these and the
controller will be damaged.
Motors with a power consumption higher than 1000 Watt must be operated via a relay
or contactor with a separate mains supply lead.
170