K - POSSIBLE PROBLEMS
Possible
Probable causes / Corrective action
problems
The burner does
–
Poor gas supply.
not light up
–
Regulator not operating properly.
–
Pipe, valve, venturi tube or burner
holes obstructed.
–
The battery may be weak. Check
the battery.
The burner
–
Check that gas is present.
does not burn
–
Check the pipe connection.
smoothly or
–
Contact your servicing agent.
goes out
Unstable
–
New cylinder may contain air. Allow
blowing flames
the device to operate and the fault
will clear itself.
–
Residual
washing of the burner caps.
–
Contact your servicing agent.
Large plume
–
The venturi is obstructed (possibly
of flame on the
cobwebs). Clean the venturi.
burner surface
–
Contact your servicing agent.
Flame at the
–
The cylinder is almost empty.
injector
–
Contact your servicing agent.
Burning leak
–
Shut off the gas supply immediately.
around a union
–
Leaking union: tighten nuts or
change pipe.
–
Contact your servicing agent.
Insufficient heat
–
Injector or venturi tube obstructed.
–
Contact your servicing agent.
Burning leak
–
Defective valve.
behind the
–
Shut down the appliance.
adjustment knob
–
Contact your servicing agent.
The burner does
–
One of the 3 burners or electrodes
not light up using
(16) may be wet. Dry them.
the electronical
–
The battery may be weak. Check
lighting but does
the battery.
with a match.
–
Contact your servicing agent.
water,
following
the
21
GB