Download Inhoudsopgave Inhoud Print deze pagina

BFT SP 3500 Installatievoorschriften pagina 24

Actuator voor schuifhekken met tandheugel
Verberg thumbnails Zie ook voor SP 3500:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 52
14) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
14.1) TESTED DEVICES Fig. O
14.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. H
15) CALLING UP MENUS: FIG. 1
15.1) PARAMETERS MENU (PARA ) (PARAMETERS TABLE "A")
15.2) LOGIC MENU (LOGIC) (LOGIC TABLE "B")
15.3) DEFAULT MENU (default)
Restores the controller's DEFAULT factory settings.
15.4) LANGUAGE MENU (language)
Used to set the programmer's language on the display.
15.5) STATISTICS MENU (STAT)
Used to view the version of the board, the total number of operations (in hundreds), the
number of transmitters memorized and the last 30 errors (the first 2 digits indicate the
position, the last 2 give the error code). Error 01 is the most recent.
15.6) PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access the
programming menus. After 10 consecutive failed attempts to log in, you will need to wait 3
minutes before trying again. During this time, whenever an attempt is made to log in, the
display will read "BLOC". The default password is 1234.
16) OPENING DIRECTION REVERSAL (FIG. N1)
If the "op.dir.rev. " logic is on 1 the opening direction is reversed in comparison with the
standard operation and the limit switches are interpreted the opposite way.
17) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD PROGRAMMER
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
 10
300
OPEN WORK. T
 10
300
CLS WORK. T
0
180
TCA
TRF. L GHT.
1
180
CLR. T
PARTIAL
3
300
OPENING
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGIC MENU - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
Step-by-step
STEP-BY-STEP
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
24 -
SP 3500 - SP 3500 SF
INSTALLATION MANUAL
Default
Personal
Definition
300
 
Opening operation time [s]
300
 
Closing operation time [s]
40
Automatic closing time [s]
Time-to-clear traffic light
40
zone [s]
5
Partial opening time[%]
Programming number of
0
operations for maintenance
threshold [in hundreds]
Cross
out
Default
setting
used
0
0
 
1
0
0
 
1
0
1
0
 
2
0
0
 
1
0
1
0
 
2
3
VERSION> V1.40 (Fig. B) Refer to specific manual.
18) RADIO-RECEIVER (Fig. I)
The board comes ready for connection of removable radio-receiver.
The receiver's channel 1 controls input IC1.
The receiver's channel 2 controls terminals 26-27.
19) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using an appropriate
antenna tuned to 433MHxz.
20) OPPOSING SLIDING DOORS (FIG.R)
REFER TO THE INSTRUCTIONS FOR THE U-LINK MODULES
WARNING: In the opposite leaves configuration, the SAFE 2 of the MASTER must be set as edge.
The configuration of the SAFE 2 safety logic, set in the Master control unit, is valid also for the
Slave control unit.
21) RESTORING FACTORY SETTINGS (Fig.S)
WARNING: this operation will restore the control unit's factory settings and all transmitters
stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to people and animals.
- Cut off power to the board (Fig.S ref.1)
- Open the Stop input and press the - and OK keys together (Fig.S ref.2)
- Switch on the board's power (Fig.S ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.S ref.4)
- Wait for the procedure to finish (Fig.S ref.5)
- Procedure finished (Fig.S ref.6)
22) WIRING DIAGRAM OF THE ONBOARD CONTROLLER FIG. P-Q
Maximum motor operation time, during opening.
Set the operation time so that it's slightly longer than the complete operating cycle time.
Maximum motor operation time, during closing.
Set the operation time so that it's slightly longer than the complete operating cycle time.
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
Partial opening time following the activation of the PED pedestrian control. It must be less
than the opening work time.
Allows you to set a number of operations after which the need for maintenance will be reported
on the AUX output configured as Maintenance or Flashing Light and Maintenance .
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman
mode is enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse operation during opening.
Deadman mode during closing.
Input 64 is configured as PULSE OPEN.
Input 65 is configured as CLOSE UP.
WARNING: safety devices are not enabled during closing.
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
STOP + TCA
OPENS

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Sp 3500 sf

Inhoudsopgave