x2
***
0---
10--
ALT
follow the user guide
language
Control unit software version
stat
OK
vers
- +
No total
manoeuvres (in hundreds)
OK
n. cycles
- +
List of last 30 errors
err
OK
0---
password
20 -
SP 3500 - SP 3500 SF
ACCESS MENUS Fig. 1
150-
1520
See PARAMETERS MENU
See LOGIC MENU
Diagnostics code
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
BAR
BAR 2
bar c
bar o
SWC
SWO
rls
ER01
ER02
ER03
ER04
ER06
ER07
ER08
bft . . .
+/-
ER1x *
ER4x *
0000
+/-
ER70-ER71
ER74-ER75
01.33
ER72
02.01
........
ER73
30.15
+/-
ErFx*
ERF3
10--
ok
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
PHOT photocell input activated
PHOT OP opening photocell input activated
PHOT CL closing photocell input activated
BAR safety edge input activated
BAR safety edge input activated on slave motor
(opposite leaves connection)
Closing safety edge input activated
Opening safety edge input activated
SWC motor closing limit switch input activated
SWO motor opening limit switch input activated
Mechanical release activated
Photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
8k2 safety edge test failed
Opening safety edge test failed
safety edge test failed
Board hardware test error
Thermal cutout
Internal system supervision control error.
Consistency error of the control unit's parameters
(Logics and Parameters)
D-track parameter error
limit switch error
error in setting SAFE inputs
*X= 0, 1, .., 9, A, B, C, D, E, F
150-
1520
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
Check position of release
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/
logic setting
Check photocell connection and/or parameter/
logic setting
Check safety edge connection and/or parameter/
logic settings
Check safety edge connection and/or parameter/
logic settings
Check safety edge connection and/or parameter/
logic settings
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
Allow automated device to cool
Try switching the board off and back on again. If
the problem persists, contact the technical assis-
tance department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters
and Logics)
Pressing OK, the board will keep on working with
D-track as a default.
An autoset is required
check limit switch connections
Check the correct setting of the SAFE inputs
prg