Technical data
Hob dimensions
Width
Depth
Built in height
Gas original:
Gas replacement:
Gas connection: R 1/2"
Burner type Injector mark
Rapid (large)
594 mm
510 mm
44 mm
TOTAL POWER
G25.3 (2EK) 25 mbar = 7.75 kW
G25 (2L) 25 mbar = 7.75 kW
G30/G31 (3B/P) 30/30 mbar = 567 g/h
G20 (2E) 20 mbar = 7.75 kW
Nominal Pow‐
er kW
G25.3 25 mbar / G25 25 mbar
115x
2.75
Other technical data
Class Appliance: 3
Appliance Category: II2EK3B/P;
II2L3B/P
Appliance gas supply: Natural gas
G25.3 (2EK) 25 mbar; G25 (2L) 25
mbar
This model is designed for use
with natural gas G25.3 25 mbar /
G25 25 mbar but can be
converted for use with natural
gas G20 20 mbar, butane or
propane gas G30/G31 30/30 mbar
providing the correct injectors.
The injectors not supplied with
the appliance have to be ordered
from After Sales Service (refer to
the Service chapter).
Nominal Flow
Reduced Pow‐
g/h
-
by-pass
er kW
0.75
42
14