Download Inhoudsopgave Inhoud Print deze pagina

Technical Data - IKEA LAGAN Handleiding

Verberg thumbnails Zie ook voor LAGAN:
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

ENGLISH
If the appliance is misused
wrongly or installed not by
authorised technician, the service
is not free of charge, even during
the warranty period.

Technical data

Hob dimensions
Width
Depth
Built in height
Gas original:
Gas replacement:
Gas connection: R 1/2"
Burner type Injector mark
Rapid (large)
594 mm
510 mm
44 mm
TOTAL POWER
G25.3 (2EK) 25 mbar = 7.75 kW
G25 (2L) 25 mbar = 7.75 kW
G30/G31 (3B/P) 30/30 mbar = 567 g/h
G20 (2E) 20 mbar = 7.75 kW
Nominal Pow‐
er kW
G25.3 25 mbar / G25 25 mbar
115x
2.75
Other technical data
Class Appliance: 3
Appliance Category: II2EK3B/P;
II2L3B/P
Appliance gas supply: Natural gas
G25.3 (2EK) 25 mbar; G25 (2L) 25
mbar
This model is designed for use
with natural gas G25.3 25 mbar /
G25 25 mbar but can be
converted for use with natural
gas G20 20 mbar, butane or
propane gas G30/G31 30/30 mbar
providing the correct injectors.
The injectors not supplied with
the appliance have to be ordered
from After Sales Service (refer to
the Service chapter).
Nominal Flow
Reduced Pow‐
g/h
-
by-pass
er kW
0.75
42
14

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Inhoudsopgave