• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from
flammable materials, etc....).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
flue cleaning.
• The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 15).
• It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible materials
and in one-room flats.
• The installation in one-room flats is allowed if they are in sealed chamber.
• In any case the stove must not be installed in rooms where it can get in touch with water or water splashes
because this can cause burn hazards and short-circuit.
• To install more appliances, the external air inlet must be correctly dimensioned (see EXTERNAL AIR INLET page
9).
9.2
OVERALL DIMENSIONS
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
Fig. 12 - General dimensions
LEGEND
Fig. 12 page 13
1
48,6 - 55 -57 cm
2
95 cm
3
46,6 - 47 cm
4
26,5 cm
5
17 cm
6
13,2 cm
7
Exhaust fumes d.8 cm
8
Hole combustion air inlet d.4 cm
EN
13