Code
Fault
Tank stop mode: Gas operation is
blocked for 15 minutes.
The door is opened for more than
2 minutes.
W10
+ beep
ERROR type fault messages
All faults of the ERROR type must be reset manually:
➤ Press the control knob for 2 seconds.
✓ A beep sounds.
✓ The error has been reset.
Code
Fault
E03
No connection between power
module and display
E07
No cooling capacity in gas mode
E08
No cooling power in AC mode
E09
No cooling power in DC mode
E12
Gas valve check error
34
Solution
Wait 15 minutes or switch to another
operating mode.
Close the door.
Solution
Contact an authorized customer service.
Check if the device is at an angle and adjust it
if necessary.
Reset the error.
Contact customer service if this error occurs
again.
Check if the device is at an angle and adjust it
if necessary.
Reset the error.
Contact customer service if this error occurs
again.
Check if the device is at an angle and adjust it
if necessary.
Reset the error.
Contact customer service if this error occurs
again.
Gas operation is not possible.
Reset the error.
Contact customer service if this error occurs
again.
RMDT10