Bijlage
Function group
RELAY
(with software option only)
R
Function group
ALPHA TABLE
T
Function group
CONCENTRATION
K
Function group
SERVICE
S
Function group
E+H SERVICE
E
Function group
INTERFACE
I
Function group
DETERMIN. OF
TEMPERATURE
COEFFICIENT
(with
software option only)
D
Function group
REMOTE
PARAMETER SET
SWITCHING
(MRS)
M
100
Selection of
Selection of contact
switch-on point
function
Alarm
;
2000 mS/cm; 99.99 %
Limit;
entire meas. range
Alarm+limit
R1
Selection of
Selection of
tables
table option
1
1 ... 4
read
(>1 with software option
edit
only)
T1
Multiplication factor
Selection of active
for concentration value
concentration table
of a user table
NaOH
; H SO ;
(with user tables only)
2
4
1
H PO ; HNO
3
4
3
0.5 ... 1.5
User
1
... 4
K1
Selection of
Selection of
language
HOLD effect
ENG
; GER
froz = last value
ITA; FRA
fixed = fixed value
ESP; NEL
S1
Module selection
Software
version
SW version
Sens = sensor
E1(4)
Software
version
MainB =
E1(3)
SW version
Mainboard
Software
version
Trans =
SW version
E1(2)
Transmitter
Software
version
Contr = Controller
SW version
E1(1)
Tag description
Entry of address
HART:
0
... 15
PROFIBUS: 1 ...
126
I1
@@@@@@@@
Entry of
Display of
compensated
uncompensated
conductivity
conductivity
current value
current value
0 ... 9999
0 ... 9999
D1
Selection of binary
Display of current
inputs for MRS
parameter set
2
1
0 ... 2
1 ... 4 if M1=0
M1
Selection of contact
Pickup delay
switch-off point
setting
2000 mS/cm; 99.99 %
0 s
entire meas. range
0 ... 2000 s
R2
R3
Selection of
Entry of number
table value pair
of value pairs in table
1
1
1 ... number of T3
1 ... 10
assign
T3
T2
Selection of
Selection of
tables
table option
1
1 ... 4
read
(>1 with software
edit
option only)
K2
K3
Entry of
HOLD configuration
fixed value
none = no HOLD
(only if S2 = fixed)
S+C = during setup
0
0 ... 100 %
Setup = during setup
of 20 or 16 mA
CAL = dur. calibration
S2
S3
Hardware
Display of
serial number
version
HW version
E141
E142
Display of
Hardware
serial number
version
HW version
E131
E132
Display of
Hardware
serial number
version
HW version
E121
E122
Display of
Hardware
version
serial number
HW version
E111
E112
I2
Display of
Entry of
current temperature
determined Alpha value
2.10 %/K
current value
–35 ... +250 °C
D2
D3
Selection of oper. mode
Selection of
parameter set
cond = conductivity
1
conc = concentration
1 ... 4 if M1=0
1 ... 2 if M1=1
M2
M3
Smartec CLD134
Dropout delay
setting
0 s
0 ... 2000 s
R4
Entry of
temperature value
(x value)
0.0 °C
–35.0 ... 250.0 °C
T4
Entry of number of
value pairs in table
4
1 ... 16
K4
Manual HOLD
and calibration
off
on
S4
Entry of
serial number
yes
no
E144
E143
E133
E123
E113
D4
Selection of medium
NaOH
; H SO ;
2
4
H PO ; HNO ;
3
4
3
User 1 ... 4
(if M4=conc)
M4
Endress+Hauser
R5
T5
K5
S5
M5