Error
Nr.
Beschrijving
Sub-
trip
100
101
102
103
104
105
106
107
≥ 200 Trip codes ≥ 200 raadpleeg de SI-EtherCAT handleiding
Sub-
trip
0
100
101
≥ 200 Trip codes ≥ 200 raadpleeg de SI-DeviceNet handleiding
Sub-
trip
0
100
101
≥ 200 Trip codes ≥ 200 raadpleeg de SI-CANopen handleiding
Unidrive M300 Handleiding versie 5.6
Error codes
Unidrive M300
SI-EtherCAT moduulcode 431 (#15.001 = 431)
Text string
Invalid Fdbk Scr
ECAT Int Error
TO ECAT PDO
Sync Task Orun
Scaling Failure
APLS Failure
TO ECAT STOP
Pre Task Overrun
SI-DeviceNet moduulcode 447 (#15.001 = 447)
Text string
No trip
Link loss
Bus Off
SI-CANopen moduulcode 448 (#15.001 = 448)
Text string
No trip
Link loss
Bus Off
Bijzonderheden
Beschrijving
Unknown or invalid feedback source has been configured
Error while initializing the EtherCAT communications
A PDO not been written for longer than specified timeout
The synchronous task has overrun its allowed interval
Configured gear ratio or feed constant values fail to be
implement in AMC
Configured additional position loop scaling fails to be
implement in AMC
The Master has requested a STOP
The Pre critical task has overrun
Beschrijving
No trip
The link to the network has been lost
The CAN layer of the module entered the Bus Off state
Beschrijving
No trip
The link to the network has been lost
The CAN layer of the module entered the Bus Off state